Paper becomes brittle, film develops vinegar syndrome, and metal corrodes long before humidity alone looks dangerous. The cause is airborne acid — and most archive dehumidifiers do nothing about it. CJS-HP100B handles humidity and acid gases in one cabinet.
Three mechanisms act at the same time. Controlling only the first one is why archives keep degrading in a room that “has a dehumidifier”.
SO₂, NO₂ and organic acids from urban air, wood shelving and paper itself hydrolyse cellulose. Paper loses fold strength and turns brittle; acetate film releases acetic acid and enters vinegar syndrome.
High RH drives mould and hydrolytic breakdown. Rapid swings stress bound materials. ISO 11799 recommends 30–50% RH with limited fluctuation for paper records.
Acid attack accelerates as moisture rises. Drying the air slows it, but only removing the gases stops the source of the attack.
CJS-HP100B is a combined acid-removal dehumidifier and humidifier. It dehumidifies to setpoint, removes acidic gases through a molecular filter stage, and can humidify when a dry climate pulls RH below the archival band.
Removes moisture to hold the room inside the archival band instead of cycling on and off around it.
Multi-stage filtration with a molecular acid-removal filter stage, so the air returning to the stacks is not carrying the acids back in.
For heated reading rooms and winter dry spells, where RH falls below the recommended minimum.
These are the numbers from the type-test report, not marketing estimates.
| Dehumidification capacity | 4.52 kg/h |
|---|---|
| Humidification capacity | 7.53 kg/h |
| PM2.5 particle removal | >99.9% |
| Rated power | 225.3 W |
| Test report | 2023AK-0060, National Air-conditioning Equipment Quality Inspection & Testing Center |
Deed rooms, land registries and permanent paper collections where the retention period is measured in centuries.
Reserve collections, textile and metal stores, and display rooms that share air with workshop and visitor areas.
Acetate and colour film stores where vinegar syndrome is the dominant risk and cold, dry, low-acid air is the defence.
Hospital, pharmaceutical, legal and insurance record rooms with statutory retention and audit obligations.
It depends on room volume, air exchange, insulation and the internal moisture load from people and paper. Sizing by floor area alone is how archive rooms end up under-specified. Send us the room drawing and we will return a sizing calculation with the unit count.
Yes. Air passes through a particulate and molecular filter stage while the refrigeration circuit conditions the temperature and humidity, so both are treated in the same air path.
Supplier-reported efficiency is ≥99.9%. The independent report we hold (2023AK-0060) does not cover acid gases — it covers dehumidification, humidification, PM2.5 and power. For a tender that requires gas-phase test data we will commission a third-party retest for the project.
The molecular acid-removal filter is a consumable. Replacement interval depends on ambient pollutant load and running hours, so it is quoted per project rather than as a fixed calendar period.
Units ship by sea or air freight depending on urgency. We quote FOB or CIF, and can work with your forwarder. Duties and import taxes are the buyer’s responsibility.
Reserve collections, textiles and metals.
Rare books and acidic paper.
Acetate film and magnetic tape.
Email your room dimensions, current RH readings if you have them, and the retention requirement. You will get a sizing recommendation and a quotation — not a brochure.