Museum Storage Climate Control: Stop the Pollutants, Not Just the Damp

A store can sit at perfect RH and still lose silver, textiles and paper — because the damage is airborne. This is the case for treating acid gases as a storage variable, not an afterthought.

See CJS-HP100B specs

The pollutants nobody measures

Most museum stores are checked for temperature and relative humidity. Almost none are checked for what is in the air — and for mixed collections that is often the faster damage route.

Silver and copper tarnish

Hydrogen sulphide and other reduced sulphur compounds blacken silver and corrode copper alloys at concentrations far below the smell threshold. A sealed showcase concentrates them.

Textiles and paper hydrolyse

Acidic gases attack cellulose and protein fibres. The fabric does not look wet, but fold strength falls year after year.

Off-gassing from the store itself

Wood, MDF, some foams and paints release acetic and formic acid. A new case can be the strongest pollutant source in the room.

Ozone and urban air

Ozone fades dyes and accelerates rubber and polymer ageing. It enters with ventilation and with visitors.

Filtration and ventilation dilute pollutants, but they also bring in outdoor air. A recirculating unit that removes acidic gases lets you keep the room closed and stable instead.

What CJS-HP100B does in a store

Holds the humidity band

Dehumidifies and, when needed, humidifies, so RH stays inside the band you set instead of swinging with the seasons.

Removes acidic gases continuously

A molecular acid-removal filter stage treats the recirculated air, targeting the acids that off-gassing and visitors keep adding.

Filters particulates

PM2.5 removal above 99.9% per the type-test report, which also keeps dust off open displays.

Figures we can defend: dehumidification 4.52 kg/h, humidification 7.53 kg/h, PM2.5 >99.9%, rated power 225.3 W — all from report 2023AK-0060. Acid-gas efficiency is supplier-reported (≥99.9%) and is not covered by that report; for a tender we will commission a third-party gas-phase retest.

Sizing a store is not sizing a room

A museum store usually has low air exchange, dense shelving and intermittent occupancy. That means the moisture load is small but the pollutant load accumulates. We size on volume, air exchange, internal load and the material mix — not on floor area. Send the drawing and the shelving layout.

Questions buyers actually ask

Can one unit serve both a store and a display gallery?

Not well. The two spaces have different loads and different opening hours. Treating them as one zone usually means the store is oversized and the gallery is under-served. We size them separately and let you stage the purchase.

Will removing acidic gases also remove the smell of a new case?

It removes the acids, which are part of what you smell, but it does not replace the recommendation to air out and off-gas new case materials before loading them.

Do you supply the monitoring?

We can quote a controller that logs temperature and RH. Gas-phase monitoring for SO₂ and acetic acid is a separate instrument category and we will say so rather than imply our unit does it.

How do you handle a mixed collection with conflicting targets?

You pick the most sensitive material class as the controlling target and accept that the rest sit inside a wider band. We will lay out those trade-offs in the sizing note.

What is the lead time for a museum project?

Units are built to order. Sea freight plus customs typically dominates, so tell us the opening date and we work backwards from it.

Other environments we spec for

National and municipal archives →

Deed rooms and permanent paper collections.

Library special collections →

Rare books and acidic paper.

Film and AV archives →

Acetate film and magnetic tape.

Send the room, get the sizing

Email the room dimensions, current RH readings and the retention requirement. You get a sizing recommendation and a quotation — not a brochure.

WhatsApp +86 177 1055 7225