Deacidification treats the sheet. The air keeps delivering new acid. This page is about the second half of the problem — and why a room at 45% RH can still be losing its collection.
Rag paper from 1750 often survives better than a 1950 paperback. The difference is the furnish: groundwood pulp and rosin-alum sizing left lignin and acid in the sheet, and those build on themselves.
Hydrolysis breaks cellulose chains. The sheet yellowed before it reached your shelf, and it keeps going.
SO₂ and NO₂ from urban air, plus acetic acid from wooden shelving and storage boxes, add to what is already in the sheet.
Every percentage point of RH speeds the reaction. Damp air does more damage to acidic paper than to any other common library material.
Brittle paper fails at the fold. A book that is never requested still degrades chemically in the stack.
Mass deacidification treats what is in the sheet. It does nothing about what the air keeps delivering — which is why a treated collection can re-acidify in a polluted store.
ISO 11799 puts document storage in that band with limited fluctuation. Wide swings do more damage than a steady value at the edge.
Recirculating filtration with a molecular acid-removal stage reduces the acid load that would otherwise deposit on the collection.
Particulates carry adsorbed acids and act as abrasive grit during handling. PM2.5 removal above 99.9% per report 2023AK-0060.
A reading room has people, doors and daylight, and it usually shares a wall with the stacks. Closing the store and conditioning it separately is better than trying to keep both at archival targets. We will size the store alone if that is what the building allows.
Humidity is one of two variables. If the room is in a polluted urban area, or has wooden shelving, the acid load can keep rising while RH looks correct. That is the case for gas-phase filtration.
No. Deacidification treats the paper; this treats the air. A treated collection in an acidic store will re-acidify.
It is a standalone recirculating unit, so it needs floor space, a power supply and condensate handling, not ductwork.
It is a consumable and the interval depends on pollutant load and running hours. We quote it per project rather than as a calendar figure.
Holding RH in band removes the condition mould needs. Existing mould needs remediation first — a dehumidifier does not clean a contaminated collection.
Deed rooms and permanent paper collections.
Reserve collections, textiles and metals.
Acetate film and magnetic tape.
Email the room dimensions, current RH readings and the retention requirement. You get a sizing recommendation and a quotation — not a brochure.